| Thermally Efficient
Daylight |
| Part L, energy efficiency
and target U values |
 |
 |
| New energy efficiency legislation is due in 2005 and
is expected to tighten the Regulations further. Energysaver FAIR can be installed at no extra effort
and minimal additional cost, making it sensible to install
rooflights with a U value of at least 2.2 W/m² K. |
| |
| Opaque
roof area with 0.25W/m² K U value |
Rooflight
area |
Required
rooflight U value W/m² K |
Rooflight
type |
| 69% |
31% |
1.5 |
Energysaver GRP or polycarbonate FAIR |
| 80% |
20% |
2.2 |
Energysaver GRP or polycarbonate FAIR |
| 86% |
14% |
3.0 |
Double skin GRP or polycarbonate FAIR |
| 88% |
12% |
3.5 |
Double skin GRP or polycarbonate FAIR |
| 90% |
10% |
4.1 |
Double skin GRP or polycarbonate FAIR |
|
|
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
|